- Characteristic and Advantage
- Electrical Characteristics
- Support ISO/IEC15693,ISO18000-3 protocol tags;
- RF output power over 4W;
- Advanced anti-collision algorithm, high identification rate, typical tag process speed is over 80 tags/s;
- Support standard 50ohm RFID antenna with effective distance up to 90cm*;
- Antenna open/short circuit tolerant;
- Support Scan-mode①;
- Support Transparent Command operation②;
- Support addressable multiple antenna ports;
- Support DPPM/WPPM tag-parsing mode③;
- Support reader network;
- Low power dissipation design;
- Provide DLL and Demonstration Software Source code to facilitate further development.
Absolute Maximum Rating
ITEM | SYMBOL | VALUE | UNIT |
Power Supply | VCC | 16 | V |
G_IN1, G_OUT1, G_OUT2 I/O Voltage | VIO | 7 | V |
Operating Temp. | TOPR | -20 ~ +65 | ℃ |
Storage Temp. | TSTR | -25 ~ +80 | ℃ |
Electrical and Mechanical Specification
Under TA=25℃,VCC=+12.6V unless specified
ITEM | SYMBOL | MIN | TYP | MAX | UNIT | |
Power Supply | VCC | 11.6 | 12.6 | 15 | V | |
Current Dissipation | IC | 0.8 | 1.2 | A | ||
Frequency | FREQ | 13.56 | MHz | |||
Effective Distance* | DIS | 0 | 900 | 1000 | mm | |
G_IN1 Input Level | VIH | 3.5 | 2.6 | 1.55 | V | |
G_OUT1, G_OUT2 | ±IO | 0.5 | mA | |||
G_OUT1, G_OUT2 | VOH(IO=-0.1mA) | 3.95 | 0.73 | V | ||
Relay | Rated Load | CLOAD | 0.5A at 125VAC | |||
Operating Voltage | 125VAC | V | ||||
Operating Current | 1 | A |
Remark:
①Scan-mode: It refers to reader’s automatic working mode.
②Transparent Command Operation: It is an advanced feature designed to support tag’s future functions and different chip vendors’ customized tag functions.
③DPPM/WPPM Tag-parsing Mode: DPPM tag-parsing mode means depth-first parsing pattern and WPPM means breadth-first parsing pattern. They are different methods of decoding multiple tags.